6-Axis Upper Neck Load Cell - H3, HF, HM, Y7, S2
6-Axis Upper Neck Load Cell - H3, HF, HM, Y7, S2
for application in crash measuring to measure the forces and moments inside the dummy. This load cell is compatible with Denton type 1716.
Technical data as follows:
- Fullbridge with 350 Ohm
- Measurement ranges:
o Fx = 8,9 kN; Fy = 8,9 kN; Fz = 13,5 kN
o Mx = 285 Nm; My = 285 Nm; Mz = 285 Nm
- Output F.S. typically
o Fx and Fy = 1,6 mV/V; Fz = 1,2 mV/V
o Mx and My = 1,6 mV/V; Mz = 2,3 mV/V
- Supply voltage up to 15 V
- Nonlinearity typically 1 %
- Hysteresis typically 1 % according to FSR
- Cable type CM16A30-SH70
- Polarity of axis according to S.A.E. J-211
Equivalent products:- DEN/1716; IF-205; DEN/2896